1.0 Identity and Manufacturer
| Identity:
Magnesite
(Magnesium Oxychloride) bonded abrasive products |
|
Manufacturer: Anchor Abrasives Company 7651 West 185th Street Tinley Park, Illinois 60451 Date Prepared: October 1, 2005 |
Phone: |
2.0 Hazardous Ingredients / Identity Information
|
Component |
CAS # |
OSHA PEL |
ACGIH TLV |
Wt. % |
|
Aluminum Oxide |
1344-28-1 |
15 mg/m3 |
10 mg/m3 |
50-90 |
|
Silicon Carbide |
409-21-2 |
15 mg/m3 |
10 mg/m3 |
50-90 |
|
Magnesium Oxide
|
1309-38-4
|
15 mg/m3
|
n/a |
0-3
|
|
Magnesium Oxychloride
|
n/a |
n/a |
n/a |
20-30
|
|
Inert Fillers |
n/a |
15 mg/m3 |
15 mg/m3 |
0-30 |
3.0 Physical / Chemical Characteristics
|
Boiling Pt.: n/a Vapor Pressure: n/a Vapor Density: n/a Solubility In Water: Insoluble Appearance and Odor: White to Blue White solid, no odor. |
Specific Gravity: 1.5 - 3.0 g/cc Melting Point: n/a Evaporation Rate: n/a |
4.0 Fire and Explosion Hazard Data
|
Flash Point: n/a Extinguishing Media: Water Special Procedures: None Unusual Hazards: None |
Flammable Limits: For
Dust |
5.0 Reactivity Data
|
Stability: Stable Conditions to avoid: None Known Incompatibility: Strong Organic Oxidizers |
Hazardous Decomposition: n/a Hazardous Polymerization: Will not occur |
6.0 Health Hazard Data
| Routes of entry: | Inhalation: TLV 10 mg/m3 | Skin: n/a |
Ingestion: n/a |
| Health Hazards: |
Acute: Inhalation of dust generated during use may cause coughing or shortness of breath. Chronic: Prolonged exposure above TLV may cause respiratory problems. |
||
|
Carcinogenicity: n/a Signs and Symptoms of Overexposure: Choking sensation Medical
conditions aggravated by overexposure: Pre-existing Pulmonary
conditions which Emergency and First Aid Procedures: Remove to dust free area. |
|||
7.0 Precautions for Safe Handling and Use
|
Steps to be taken in case of spill: Collect in most convenient and safe manner for disposal. Waste Disposal Method: In accordance with Federal, State, and Local regulations as a dry solid. Storage
/ Handling Precautions: Handle in accordance with ANSI B7.1 Other Precautions: Inspect disc for damage upon arrival and prior to mounting. |
| Respiratory Protection: NIOSH approved respiratory protection recommended if TLV is exceeded. | |
|
Venitlation Local: To remove dust during use Gen.: Mechanical Dust collection system Spec.: n/a |
|
|
Protective Gloves: Suitable for grinding Eye Protection: Safety glasses are highly recommended. Other Protection: As required for a grinding operation. Work/Hygienic Practices: n/a |
|
Disclaimer: All information and recommendations appearing on this Safety Data sheet are based upon data believed to be reliable. It is the user's responsibility to determine the suitability for their own use and to comply with all applicable regulations. No guarantee, either expressed or implied is made by Anchor Abrasives Company as to the safety and toxicity of the product, nor does Anchor Abrasives Company assume any liability arising from the use of this product.